000 -LEADER |
fixed length control field |
05894nam a2200709 i 4500 |
001 - CONTROL NUMBER |
control field |
7416055 |
003 - CONTROL NUMBER IDENTIFIER |
control field |
IEEE |
005 - DATE AND TIME OF LATEST TRANSACTION |
control field |
20200413152920.0 |
006 - FIXED-LENGTH DATA ELEMENTS--ADDITIONAL MATERIAL CHARACTERISTICS |
fixed length control field |
m eo d |
007 - PHYSICAL DESCRIPTION FIXED FIELD--GENERAL INFORMATION |
fixed length control field |
cr cn |||m|||a |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION |
fixed length control field |
160122s2016 caua foab 000 0 eng d |
020 ## - INTERNATIONAL STANDARD BOOK NUMBER |
International Standard Book Number |
9781627058469 |
Qualifying information |
ebook |
020 ## - INTERNATIONAL STANDARD BOOK NUMBER |
Canceled/invalid ISBN |
9781627058452 |
Qualifying information |
print |
024 7# - OTHER STANDARD IDENTIFIER |
Standard number or code |
10.2200/S00691ED1V01Y201512EET002 |
Source of number or code |
doi |
035 ## - SYSTEM CONTROL NUMBER |
System control number |
(CaBNVSL)swl00406112 |
035 ## - SYSTEM CONTROL NUMBER |
System control number |
(OCoLC)935806899 |
040 ## - CATALOGING SOURCE |
Original cataloging agency |
CaBNVSL |
Language of cataloging |
eng |
Description conventions |
rda |
Transcribing agency |
CaBNVSL |
Modifying agency |
CaBNVSL |
050 #4 - LIBRARY OF CONGRESS CALL NUMBER |
Classification number |
QC670 |
Item number |
.C272 2016 |
082 04 - DEWEY DECIMAL CLASSIFICATION NUMBER |
Classification number |
530.141 |
Edition number |
23 |
100 1# - MAIN ENTRY--PERSONAL NAME |
Personal name |
Cataldo, Andrea., |
Relator term |
author. |
245 10 - TITLE STATEMENT |
Title |
Advances in reflectometric sensing for industrial applications / |
Statement of responsibility, etc. |
Andrea Cataldo, Egidio De Benedetto, and Giuseppe Cannazza. |
264 #1 - PRODUCTION, PUBLICATION, DISTRIBUTION, MANUFACTURE, AND COPYRIGHT NOTICE |
Place of production, publication, distribution, manufacture |
San Rafael, California (1537 Fourth Street, San Rafael, CA 94901 USA) : |
Name of producer, publisher, distributor, manufacturer |
Morgan & Claypool, |
Date of production, publication, distribution, manufacture, or copyright notice |
2016. |
300 ## - PHYSICAL DESCRIPTION |
Extent |
1 PDF (xi, 84 pages) : |
Other physical details |
illustrations. |
336 ## - CONTENT TYPE |
Content type term |
text |
Source |
rdacontent |
337 ## - MEDIA TYPE |
Media type term |
electronic |
Source |
isbdmedia |
338 ## - CARRIER TYPE |
Carrier type term |
online resource |
Source |
rdacarrier |
490 1# - SERIES STATEMENT |
Series statement |
Synthesis lectures on emerging engineering technologies, |
International Standard Serial Number |
2381-1439 ; |
Volume/sequential designation |
# 2 |
538 ## - SYSTEM DETAILS NOTE |
System details note |
Mode of access: World Wide Web. |
538 ## - SYSTEM DETAILS NOTE |
System details note |
System requirements: Adobe Acrobat Reader. |
500 ## - GENERAL NOTE |
General note |
Part of: Synthesis digital library of engineering and computer science. |
504 ## - BIBLIOGRAPHY, ETC. NOTE |
Bibliography, etc. note |
Includes bibliographical references. |
505 0# - FORMATTED CONTENTS NOTE |
Formatted contents note |
1. Introduction to microwave reflectometry -- 1.1 Introduction -- 1.2 Time domain reflectometry (TDR) -- 1.3 The sensing element -- 1.4 Brief overview of TDR applications -- 1.5 Bibliography -- |
505 8# - FORMATTED CONTENTS NOTE |
Formatted contents note |
2. Reflectometry for leak localization in underground pipes -- 2.1 Introduction -- 2.2 Survey of the state-of-the-art methods for leak detection -- 2.3 Leak localization in pipes made of any material -- 2.3.1 Measurement apparatus -- 2.3.2 Case study on a pilot plant -- 2.3.3 Description of the practical implementation -- 2.4 Leak localization in already-installed metallic pipes -- 2.4.1 Measurement apparatus -- 2.4.2 Case study -- 2.5 Conclusion -- 2.6 Bibliography -- |
505 8# - FORMATTED CONTENTS NOTE |
Formatted contents note |
3. Reflectometry for moisture monitoring in buildings -- 3.1 Introduction -- 3.2 Ex-ante monitoring of water content in building structures -- 3.2.1 Hydration process of a mortar sample -- 3.2.2 Hydration process of a concrete sample -- 3.3 Ex-post monitoring of water content in building structures -- 3.4 Practical implementation of the system: a case study -- 3.5 Conclusion -- 3.6 Bibliography -- |
505 8# - FORMATTED CONTENTS NOTE |
Formatted contents note |
4. Reflectometry for liquid-level monitoring -- 4.1 Introduction -- 4.2 Theoretical background -- 4.3 Liquid-specific level monitoring system -- 4.4 Liquid-independent level monitoring system -- 4.4.1 Test case: level monitoring in a metallic container -- 4.4.2 Test case: level monitoring in a non-metallic container -- 4.5 Theoretical analysis for the practical implementation -- 4.5.1 Level monitoring in metallic container -- 4.5.2 Level monitoring in non-metallic container -- 4.6 Conclusion -- 4.7 Bibliography -- Authors' biographies. |
506 1# - RESTRICTIONS ON ACCESS NOTE |
Terms governing access |
Abstract freely available; full-text restricted to subscribers or individual document purchasers. |
510 0# - CITATION/REFERENCES NOTE |
Name of source |
Compendex |
510 0# - CITATION/REFERENCES NOTE |
Name of source |
INSPEC |
510 0# - CITATION/REFERENCES NOTE |
Name of source |
Google scholar |
510 0# - CITATION/REFERENCES NOTE |
Name of source |
Google book search |
520 3# - SUMMARY, ETC. |
Summary, etc. |
This book offers a comprehensive review of innovative measurement and monitoring solutions based on time domain reflectometry (TDR). This technique has numerous applications in several fields, ranging from the characterization of electronic devices to quality control of vegetable oils. However, most of the well-established TDR-based monitoring solutions rely on local or punctual probes; therefore, typically, to monitor large areas/volumes, a high number of probes must be employed, with the consequent maintenance and management requirements. On such bases, in the last few years, the authors have carried out extensive research on the use of diffused wirelike sensing elements to be used as probes for TDR measurements. The basic idea has been to extend the principles of punctual TDR-based monitoring to multi-purpose networks of diffused, sensing elements (SEfs), embedded permanently within the systems to be monitored (STBMfs). These SEs can be tens of meters long, and can follow any desired path inside the STBM.; in fact, they are inactive inside the STBM. Additionally, these SEfs are passive (i.e., they do not require batteries) and their sensing ability is activated, by the TDR signal, when they are connected to the measurement instrument. In addition to this, these SEfs are completely maintenance-free. Starting from these considerations, this book addresses the use of low-cost, passive, flexible, wire-like SEfs to be used in conjunction with TDR. This book also provides several application test cases, with hints for practical implementation of the described monitoring systems. |
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE |
Additional physical form available note |
Also available in print. |
588 ## - SOURCE OF DESCRIPTION NOTE |
Source of description note |
Title from PDF title page (viewed on January 22, 2016). |
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Time-domain reflectometry. |
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Electromagnetic measurements. |
653 ## - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
microwave reflectometry |
653 ## - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
reflection coefficient |
653 ## - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
leak detection system |
653 ## - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
moisture monitoring |
653 ## - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
structural health monitoring |
653 ## - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
diffused monitoring |
653 ## - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
smart monitoring |
653 ## - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
time domain reflectometry |
653 ## - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
dielectric permittivity |
653 ## - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
dielectric characterization |
700 1# - ADDED ENTRY--PERSONAL NAME |
Personal name |
De Benedetto, Egidio., |
Relator term |
author. |
700 1# - ADDED ENTRY--PERSONAL NAME |
Personal name |
Cannazza, Giuseppe., |
Relator term |
author. |
776 08 - ADDITIONAL PHYSICAL FORM ENTRY |
Relationship information |
Print version: |
International Standard Book Number |
9781627058452 |
830 #0 - SERIES ADDED ENTRY--UNIFORM TITLE |
Uniform title |
Synthesis digital library of engineering and computer science. |
830 #0 - SERIES ADDED ENTRY--UNIFORM TITLE |
Uniform title |
Synthesis lectures on emerging engineering technologies ; |
Volume/sequential designation |
# 2. |
International Standard Serial Number |
2381-1439 |
856 42 - ELECTRONIC LOCATION AND ACCESS |
Materials specified |
Abstract with links to resource |
Uniform Resource Identifier |
http://ieeexplore.ieee.org/servlet/opac?bknumber=7416055 |