000 -LEADER |
fixed length control field |
06196nam a2200673 i 4500 |
001 - CONTROL NUMBER |
control field |
7007880 |
003 - CONTROL NUMBER IDENTIFIER |
control field |
IEEE |
005 - DATE AND TIME OF LATEST TRANSACTION |
control field |
20200413152916.0 |
006 - FIXED-LENGTH DATA ELEMENTS--ADDITIONAL MATERIAL CHARACTERISTICS |
fixed length control field |
m eo d |
007 - PHYSICAL DESCRIPTION FIXED FIELD--GENERAL INFORMATION |
fixed length control field |
cr cn |||m|||a |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION |
fixed length control field |
150117s2015 caua foab 000 0 eng d |
020 ## - INTERNATIONAL STANDARD BOOK NUMBER |
International Standard Book Number |
9781627055147 |
Qualifying information |
ebook |
020 ## - INTERNATIONAL STANDARD BOOK NUMBER |
Canceled/invalid ISBN |
9781627055130 |
Qualifying information |
print |
024 7# - OTHER STANDARD IDENTIFIER |
Standard number or code |
10.2200/S00616ED1V01Y201411BME054 |
Source of number or code |
doi |
035 ## - SYSTEM CONTROL NUMBER |
System control number |
(CaBNVSL)swl00404603 |
035 ## - SYSTEM CONTROL NUMBER |
System control number |
(OCoLC)900341046 |
040 ## - CATALOGING SOURCE |
Original cataloging agency |
CaBNVSL |
Language of cataloging |
eng |
Description conventions |
rda |
Transcribing agency |
CaBNVSL |
Modifying agency |
CaBNVSL |
050 #4 - LIBRARY OF CONGRESS CALL NUMBER |
Classification number |
QH513 |
Item number |
.S286 2015 |
082 04 - DEWEY DECIMAL CLASSIFICATION NUMBER |
Classification number |
571.43 |
Edition number |
23 |
100 1# - MAIN ENTRY--PERSONAL NAME |
Personal name |
Saunders, Marnie M., |
Relator term |
author. |
245 10 - TITLE STATEMENT |
Title |
Mechanical testing for the biomechanical engineer : |
Remainder of title |
a practical guide / |
Statement of responsibility, etc. |
Marnie M. Saunders. |
246 1# - VARYING FORM OF TITLE |
Display text |
Title from web site: |
Title proper/short title |
Mechanical testing for the biomechanics engineer. |
264 #1 - PRODUCTION, PUBLICATION, DISTRIBUTION, MANUFACTURE, AND COPYRIGHT NOTICE |
Place of production, publication, distribution, manufacture |
San Rafael, California (1537 Fourth Street, San Rafael, CA 94901 USA) : |
Name of producer, publisher, distributor, manufacturer |
Morgan & Claypool, |
Date of production, publication, distribution, manufacture, or copyright notice |
2015. |
300 ## - PHYSICAL DESCRIPTION |
Extent |
1 PDF (xix, 256 pages) : |
Other physical details |
illustrations. |
336 ## - CONTENT TYPE |
Content type term |
text |
Source |
rdacontent |
337 ## - MEDIA TYPE |
Media type term |
electronic |
Source |
isbdmedia |
338 ## - CARRIER TYPE |
Carrier type term |
online resource |
Source |
rdacarrier |
490 1# - SERIES STATEMENT |
Series statement |
Synthesis lectures on biomedical engineering, |
International Standard Serial Number |
1930-0336 ; |
Volume/sequential designation |
# 54 |
538 ## - SYSTEM DETAILS NOTE |
System details note |
Mode of access: World Wide Web. |
538 ## - SYSTEM DETAILS NOTE |
System details note |
System requirements: Adobe Acrobat Reader. |
500 ## - GENERAL NOTE |
General note |
Part of: Synthesis digital library of engineering and computer science. |
504 ## - BIBLIOGRAPHY, ETC. NOTE |
Bibliography, etc. note |
Includes bibliographical references (pages 243-254). |
505 0# - FORMATTED CONTENTS NOTE |
Formatted contents note |
1. Fundamentals -- 1.1 Basic mechanics -- 1.1.1 Mechanical properties -- 1.1.2 Loading modes -- 1.1.3 Material properties and degree of anisotropy -- 1.1.4 Fracture and fatigue -- 1.1.5 Viscoelasticity -- 1.1.6 Complex stress states -- 1.1.7 Significant digits -- |
505 8# - FORMATTED CONTENTS NOTE |
Formatted contents note |
2. Accuracy and measurement tools -- 2.1 Accuracy and precision -- 2.2 Measurement tools -- 2.2.1 Steel rule -- 2.2.2 Calipers -- 2.2.3 Micrometers -- 2.2.4 Vernier scales -- 2.2.5 Additional measurement equipment -- 2.2.6 Handling issues -- 2.2.7 A practical note -- |
505 8# - FORMATTED CONTENTS NOTE |
Formatted contents note |
3. Design -- 3.1 Mechanical drawing -- 3.2 Machining -- 3.2.1 Machine shop safety -- 3.2.2 Stock materials -- 3.2.3 Design layout -- 3.2.4 The equipment -- 3.2.5 Threading -- 3.2.6 Fixture fabrication example -- |
505 8# - FORMATTED CONTENTS NOTE |
Formatted contents note |
4. Testing machine design and fabrication -- 4.1 Mechanical testing -- 4.1.1 Force measurement -- 4.1.2 Displacement measurement -- 4.2 Fabrication of a simple loading platform -- 4.2.1 Mechanical testing platforms -- 4.2.2 Development of a simple platform -- 4.2.3 Additional linear applications -- 4.3 Expanding the simple platform beyond axial motion -- 4.3.1 Torsion -- |
505 8# - FORMATTED CONTENTS NOTE |
Formatted contents note |
5. Fixture design and applications -- 5.1 Test fixtures -- 5.1.1 Design considerations -- 5.2 Fixture design and development -- 5.2.1 Bending fixtures -- 5.2.2 Tension fixtures -- 5.2.3 Compression fixtures -- 5.2.4 Torsion fixtures -- 5.2.5 Shear applications -- 5.2.6 Miscellaneous holders -- 5.2.7 Repurposing existing fixtures -- |
505 8# - FORMATTED CONTENTS NOTE |
Formatted contents note |
6. Additional considerations in a biomechanics test -- 6.1 Additional design considerations -- 6.1.1 Know the literature -- 6.1.2 ASTM standards -- 6.1.3 Model selection -- 6.1.4 Tissue care -- 6.1.5 Equipment -- 6.1.6 Specimen attachment -- 6.1.7 Potting media -- 6.1.8 Potting alignment -- 6.1.9 Potting and testing molds -- 6.1.10 Removing molds -- 6.1.11 Small-scale specimen preparation -- 6.1.12 Material selection -- 6.1.13 Data analysis -- |
505 8# - FORMATTED CONTENTS NOTE |
Formatted contents note |
7. Laboratory examples and additional equations -- |
505 8# - FORMATTED CONTENTS NOTE |
Formatted contents note |
8. Appendices: practical orthopaedic biomechanics problems -- 8.1 Example 1: Implant design: prototype, benchtop analysis -- 8.1.1 The problem -- 8.1.2 Goal -- 8.1.3 Solution -- 8.1.4 Method -- 8.1.5 Key study concepts -- 8.2 Example 2: Cadaveric comparison of allograft fixation techniques -- 8.2.1 The problem -- 8.2.2 Goal -- 8.2.3 Solution -- 8.2.4 Method -- 8.2.5 Results -- 8.2.6 Study limitations -- 8.2.7 Key study concepts -- 8.3 Example 3: Bone removal location effect in autografting: assessing fracture risk -- 8.3.1 The problem -- 8.3.2 Goal -- 8.3.3 Method -- 8.3.4 Key study concepts -- 8.4 Example 4: Diaphyseal femur fracture after proximal and distal fixation -- 8.4.1 The problem -- 8.4.2 Goal -- 8.4.3 Method -- 8.4.4 The solution -- 8.4.5 Results -- 8.4.6 Study limitations -- 8.4.7 Key study concepts -- 8.5 Example 5: Cellular biomechanics: mechanical platforms for mechanobiology -- 8.5.1 The need -- 8.5.2 Method -- |
505 8# - FORMATTED CONTENTS NOTE |
Formatted contents note |
Bibliography -- Author biography. |
506 1# - RESTRICTIONS ON ACCESS NOTE |
Terms governing access |
Abstract freely available; full-text restricted to subscribers or individual document purchasers. |
510 0# - CITATION/REFERENCES NOTE |
Name of source |
Compendex |
510 0# - CITATION/REFERENCES NOTE |
Name of source |
INSPEC |
510 0# - CITATION/REFERENCES NOTE |
Name of source |
Google scholar |
510 0# - CITATION/REFERENCES NOTE |
Name of source |
Google book search |
520 3# - SUMMARY, ETC. |
Summary, etc. |
Mechanical testing is a useful tool in the field of biomechanics. Classic biomechanics employs mechanical testing for a variety of purposes. For instance, testing may be used to determine the mechanical properties of bone under a variety of loading modes and various conditions including age and disease state. In addition, testing may be used to assess fracture fixation procedures to justify clinical approaches. Mechanical testing may also be used to test implants and biomaterials to determine mechanical strength and appropriateness for clinical purposes. While the information from a mechanical test will vary, there are basics that need to be understood to properly conduct mechanical testing. This book will attempt to provide the reader not only with the basic theory of conducting mechanical testing, but will also focus on providing practical insights and examples. |
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE |
Additional physical form available note |
Also available in print. |
588 ## - SOURCE OF DESCRIPTION NOTE |
Source of description note |
Title from PDF title page (viewed on January 17, 2015). |
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Biomechanics. |
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Testing. |
653 ## - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
biomechanics |
653 ## - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
orthopaedics |
653 ## - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
mechanical testing |
776 08 - ADDITIONAL PHYSICAL FORM ENTRY |
Relationship information |
Print version: |
International Standard Book Number |
9781627055130 |
830 #0 - SERIES ADDED ENTRY--UNIFORM TITLE |
Uniform title |
Synthesis digital library of engineering and computer science. |
830 #0 - SERIES ADDED ENTRY--UNIFORM TITLE |
Uniform title |
Synthesis lectures on biomedical engineering ; |
Volume/sequential designation |
# 54. |
International Standard Serial Number |
1930-0336 |
856 42 - ELECTRONIC LOCATION AND ACCESS |
Materials specified |
Abstract with links to resource |
Uniform Resource Identifier |
http://ieeexplore.ieee.org/servlet/opac?bknumber=7007880 |