Welcome to P K Kelkar Library, Online Public Access Catalogue (OPAC)

Bioceramics and Alternative Bearings in Joint Arthroplasty (Record no. 502016)

000 -LEADER
fixed length control field 07419nam a22004695i 4500
001 - CONTROL NUMBER
control field 978-3-7985-1635-9
003 - CONTROL NUMBER IDENTIFIER
control field DE-He213
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20161121230645.0
007 - PHYSICAL DESCRIPTION FIXED FIELD--GENERAL INFORMATION
fixed length control field cr nn 008mamaa
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 100301s2006 gw | s |||| 0|eng d
020 ## - INTERNATIONAL STANDARD BOOK NUMBER
International Standard Book Number 9783798516359
-- 978-3-7985-1635-9
024 7# - OTHER STANDARD IDENTIFIER
Standard number or code 10.1007/978-3-7985-1635-9
Source of number or code doi
050 #4 - LIBRARY OF CONGRESS CALL NUMBER
Classification number RD701-811
072 #7 - SUBJECT CATEGORY CODE
Subject category code MNS
Source bicssc
072 #7 - SUBJECT CATEGORY CODE
Subject category code MED065000
Source bisacsh
082 04 - DEWEY DECIMAL CLASSIFICATION NUMBER
Classification number 616.7
Edition number 23
245 10 - TITLE STATEMENT
Title Bioceramics and Alternative Bearings in Joint Arthroplasty
Medium [electronic resource] :
Remainder of title 11th BIOLOX® Symposium Rome, June 30 – July 1, 2006 Proceedings /
Statement of responsibility, etc. edited by Francesco Benazzo, Francesco Falez, Martin Dietrich.
264 #1 - PRODUCTION, PUBLICATION, DISTRIBUTION, MANUFACTURE, AND COPYRIGHT NOTICE
Place of production, publication, distribution, manufacture Darmstadt :
Name of producer, publisher, distributor, manufacturer Steinkopff,
Date of production, publication, distribution, manufacture, or copyright notice 2006.
300 ## - PHYSICAL DESCRIPTION
Extent XVII, 321 p. 177 illus.
Other physical details online resource.
336 ## - CONTENT TYPE
Content type term text
Content type code txt
Source rdacontent
337 ## - MEDIA TYPE
Media type term computer
Media type code c
Source rdamedia
338 ## - CARRIER TYPE
Carrier type term online resource
Carrier type code cr
Source rdacarrier
347 ## - DIGITAL FILE CHARACTERISTICS
File type text file
Encoding format PDF
Source rda
490 1# - SERIES STATEMENT
Series statement Ceramics in Orthopaedics
505 0# - FORMATTED CONTENTS NOTE
Formatted contents note Large diameter femoral and acetabular components -- Head Diameter of 36mm: New alumina on alumina bearing surfaces -- All ceramic tripolar Total Hip Arthroplasty: experimental data and clinical results -- Clinical advantages with large diameter heads -- 36mm Ceramic head for “difficult” cases -- Resurfacing in total hip replacement -- Seven years of experience in MoM resurfacing: Results and open questions -- Surgeon and resurfacing: considerations after a long experience -- Hip Resurfacing — a superior articulation concept? -- Consideration on disadvantages and problems of resurfacing -- In vitro biomechanical properties of a hip resurfacing system -- Comparison of functional activity of hip resurfacing with total hip arthroplasty -- Hard-hard bearing systems -- Radiological development of an alumina metal back cup during 5 years -- Metal Ion Hypersensitivity in Metal-on-Metal Hip Arthroplasty -- 28mm Head in Ceramic/Ceramic Total Hip Replacement -- Ceramic Bearings Enlarging the Range of Indications for Bipolar Prostheses -- Kinematic evaluation of total hip arthroplasty with various bearing materials -- Total hip replacement with all alumina bearings in patients under 30 years of age -- Ceramic knee -- PE wear in ceramic/PE bearing surface in total knee arthroplasty: Clinical experiences of more than 24 years -- Hypersensitivity reactions in association to arthroplasty -- Ceramic Knee Design -- Ceramic knee endoprostheses: reality or future? -- Hip Revision -- Comparison of clinical results between Ceramic-Ceramic Bearings and Metal on Polyethylene in Total Hip Arthroplasty -- Revision strategy after metal on metal THR failure: Conversion to ceramic on ceramic -- Modular neck and ceramic on ceramic coupling in revision total hip arthroplasty -- Experience with BIOLOX® option revision heads -- Acetabular cup revision: pitfalls and solutions -- Revision strategies in total hip arthroplasty with respect to articulation materials -- Tribology -- Hip Joint Simulators: State of the Art -- Highly Crosslinked Ultra High Molecular Weight Polyethylene- (UHMWPE-) Acetabular Liners in combination with 28mm BIOLOX® heads -- Wear of Highly Crosslinked Polyethylene against Cobalt Chrome and Ceramic femoral heads -- US perspective on hip simulator wear testing of BIOLOX® delta in’ severe’ test modes -- Comparison of polythene liners with alumina liners in hydroxyapatite hip arthroplasty -- Edge Loading and Squeaking in Third Generation Ceramic-on-ceramic Bearings -- Tricks and tips: how to manage the implantation of ceramic implants -- Tricks and tips in every day utilization of ceramic on ceramic coupling -- Neck Modularity and CE/CE systems -- Off-set and ceramic on ceramic bearing -- Ceramic on ceramic cementless total hip arthroplasty in arthritis following congenital hip disease: an algorithm of the surgical treatment -- 32mm alumina on alumina hip replacement for femoral neck fracture -- Is there really a “safe zone” for the placement of total hip components? -- Tips of the trade: avoiding problems with ceramic components in THR -- Future Applications -- Direct to bone — possible ceramic solutions for monolithic hip implants -- Surface Activation of Implants -- Application of Bone Morphogenetic Proteins on Solid Implants -- Future applications in ceramics -- Poster -- The use of a ceramic “sandwich cup” in 140 hip arthroplasty with a 5 years follow-up or more -- THR Charnley type with Zr/Pe Bearing results at more than 5 years FU -- Wear Performance of Carbon Fibre Reinforced Implantable PEEK against BIOLOX® Forte and BIOLOX® Delta -- Big diameter ball heads on Corail Stem: Rational indication and advantages -- The Role of Pre-Irradation Crystallinity on the Oxidation Resistance of UHMWPE -- The Effect of Pressure-Annealing on the Oxidation Resistance of Irradiated UHMWPE -- Wear Simulator Study of the Tripolar All Ceramic Hip Prosthesis -- Metallic but not ceramic wear particles increase prostaglandin E2 release and interleukin-1? (IL-1?) gene expression in human blood monocytes in vitro -- BMP-2 modified ingrowth characteristics of coated hydroxyapatite-titanium implants in aged sheep -- Ultimate Compression Strength Testing of Alumina Ceramic Femoral Heads in Revision -- BIOLOX® option: A new revision strategy with BIOLOX® ceramics -- Duolox®, a ceramic Bipolar System for Hemiarthroplasty.
520 ## - SUMMARY, ETC.
Summary, etc. Dear Colleague and Participant in Bioceramics and Alternative Bearings in Joint th ® Arthroplasty: 11 International BIOLOX Symposium We are once again very proud of the fact that we have been able to provide you with the proceedings of this Symposium as a part of your registration materials. This is a mayor achievement that could only be made possible by the excellent cooperation of all of the speakers, the publishing house and their staff and the Symposium Administrator and her support staff. Our special thanks to all of them for their hard work and dedication to meet the difficult deadlines required to make this a reality. The proceedings for this Symposium continue the on-going tradition to provide all of us with a valuable and useful addition to our reference library. We hope that within its covers, you will find the most up to date scientific and clinical information regarding the use of ceramic solutions to address wear related problems in Orthopedic Surgery. This is the first time that the symposium takes place in Italy. The reason we chose Italy and in particular Rome is obvious as CeramTec has had a long term and close relationship with the Italian. CeramTec is pleased that our Symposium Chairmen, Professors F. Benazzo and F. Falez have collaborated with us in the preparation and in th the execution of Bioceramics and Alternative Bearings in Joint Arthroplasty - 11 ® International BIOLOX Symposium.
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Medicine.
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Orthopedics.
650 14 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Medicine & Public Health.
650 24 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Orthopedics.
650 24 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Surgical Orthopedics.
700 1# - ADDED ENTRY--PERSONAL NAME
Personal name Benazzo, Francesco.
Relator term editor.
700 1# - ADDED ENTRY--PERSONAL NAME
Personal name Falez, Francesco.
Relator term editor.
700 1# - ADDED ENTRY--PERSONAL NAME
Personal name Dietrich, Martin.
Relator term editor.
710 2# - ADDED ENTRY--CORPORATE NAME
Corporate name or jurisdiction name as entry element SpringerLink (Online service)
773 0# - HOST ITEM ENTRY
Title Springer eBooks
776 08 - ADDITIONAL PHYSICAL FORM ENTRY
Relationship information Printed edition:
International Standard Book Number 9783798516342
830 #0 - SERIES ADDED ENTRY--UNIFORM TITLE
Uniform title Ceramics in Orthopaedics
856 40 - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier http://dx.doi.org/10.1007/978-3-7985-1635-9
912 ## -
-- ZDB-2-SME
Holdings
Withdrawn status Lost status Damaged status Not for loan Permanent Location Current Location Date acquired Barcode Date last seen Price effective from Koha item type
        PK Kelkar Library, IIT Kanpur PK Kelkar Library, IIT Kanpur 2016-11-21 EBK2303 2016-11-21 2016-11-21 E books

Powered by Koha